Command/Response Table for SIS Commands (continued)

Command Function

SIS Command

(Host to Unit)

Response

(Unit to Host)

Additional description

Local video output sync polarity

NOTE

:

The command structure differs, depending on the size of the matrix. Matrix sizes 816, 168, and 1616 do not need the local

output variable (

X1^

). Matrix sizes 128, 1632, 3216, and 3232 require the variable.

Set local output polarity
(matrix size 816, 168, and 1616)

EX1&

Opol

}

Opol

X1&]

Set the horizontal and vertical sync
polarity for a local output.

Example:

E

0Opol

}

Opol0

]

Set the local output to output negative
horizontal and vertical sync.

Set local output polarity
(matrix size 128, 1632, 3216, and
3232)

EX1^

*

X1&

Opol

}

Opol

X1^

*

X1&]

Set the horizontal and vertical sync
polarity for local output

X1^

.

Example:

E

2*0Opol

}

Opol2*0

]

Set local output 2 to output negative
horizontal and vertical sync.

Read local output sync settings
(matrix size 816, 168, and 1616)

E

Opol

}

X1&]

Read local output sync settings
(matrix size 128, 1632, 3216, and
3232)

EX1^

Opol

}

X1&]

Output skew adjustment

Set all output skew adjustment
values

EX@

*

X1)

*

X1)

*

X1)

Oseq

}

Set a specific skew adjustment for the
TP output.

X1)

values are listed in RGB

order.

Oseq

X@

*

X1)

*

X1)

*

X1)]

Example:

E

2*0*0*4Oseq

}

Oseq02*0*0*4

]

Set the output 2 skew settings as
follows:
Red = 0 ns
Green = 0 ns
Blue = 8 ns (delayed 8 ns).

Increment one output skew
adjustment value

EX@

*

X1!

+Oseq

}

Oseq

X@

*

X1)

*

X1)

*

X1)]

Increase the

X1!

plane skew

adjustment output

X@

by 1 step (2 ns).

Decrement one output skew
adjustment value

EX@

*

X1!

-Oseq

}

Oseq

X@

*

X1)

*

X1)

*

X1)]

Decrease the

X1!

plane skew

adjustment output

X@

by 1 step (2 ns).

Example:

E

2*2-Oseq

}

Oseq02*0*0*3

]

Decrease the output 2 blue skew by 2 ns
to 6 ns.

Read output skew adjustment values

EX@

Oseq

}

X1)

*

X1)

*

X1)]

NOTE:

X@

= Output number

01 – (maximum number of outputs for your model)

X1)

= Skew adjustment range

00 – 31 (each step = 2ns)

X1!

= Video plane

0 = red

1 = green

2 = blue

X1^

= Local video output number

1 or 2 (X1^ applies to matrix sizes 128, 1632, 3216, and 3232 only)

X1&

= Local output sync polarity

0 = H- / V- (default)

1 = H+ / V-

2 = H- / V+

3 = H+ / V+

4 = No sync processing (composite, S-video, YUV)