Ethernet

Connection

This section provides a high level discussion of the Ethernet connection to the switcher and a
primer on the subject of subnetting. Topics that are covered, include:

Ethernet Link
Subnetting — A Primer

Ethernet Link

The rear panel Ethernet connector on the MTPX Plus switcher can be connected to an
Ethernet LAN or WAN. This connection makes SIS control of the switcher possible using a
computer connected to the same LAN.

Ethernet Connection

The Ethernet cable can be terminated as a straight-through cable or a crossover cable and
must be properly terminated for your application (see

figure 90

).

Crossover cable — Direct connection between the computer and the
MTPX Plus switcher

Patch (straight-through) cable — Connection of the MTPX Plus switcher to an
Ethernet LAN

A cable that is wired as T568A at one end
and T568B at the other (Tx and Rx pairs
reversed) is a "crossover" cable.

A cable that is wired the same at both ends is
called a "straight-through" cable, because
no pin/pair assignments are swapped.

12345678

RJ-45

Connector

Insert Twisted

Pair Wires

Pins:

Crossover Cable

Straight-through Cable

Pin

1

2
3
4
5
6
7
8

Wire color

White-green

Green
White-orange
Blue
White-blue
Orange
White-brown
Brown

Wire color

T568A

T568B

End 1

End 2

End 1

End 2

White-orange

Orange
White-green
Blue
White-blue
Green
White-brown
Brown

Pin

1

2
3
4
5
6
7
8

Wire color

White-orange

White-green

Blue

White-blue

White-brown

Brown

Wire color

T568B

T568B

White-orange

Orange

Orange

White-green

Blue

White-blue
Green

Green

White-brown

Brown

Figure 90.

RJ-45 Connector Pinout Tables

Default IP Address

To access the MTPX Plus switcher via the LAN port, you need the IP address of the switcher.
If the address has been changed to an address comprised of words and characters, you can
determine the actual numeric IP address using the ping utility. If the address has not been
changed, the factory-specified default is 192.168.254.254.
Ping can also be used to test the Ethernet link to the MTPX Plus switcher.