Resetting a password – Extron Electronics MTPX Plus Series User Guide User Manual

Page 138

Advertising
background image

Passwords Page

Access the Passwords page (see figure 80) by clicking the

Passwords

link on the System

Settings page.

Select Passwords

Refresh

Select Firmware Upgrade

Select Email Settings

Figure 80.

Passwords Page

NOTE: If the switcher is password protected, fields on this page can be edited only by

people logged in as administrators.

The fields on the Passwords page are for entering and verifying administrator and
user passwords. Passwords are case sensitive and are limited to up to 12 upper-
case and lower-case alphanumeric characters. Each password must be entered
twice; once in the Password field and then again in the Re-enter Password field.
Characters in these fields are masked by asterisks (

*****

). If you do not want to password

protect an access level, leave the Password field and the Re-Enter Password field blank. After
entering the password in both fields, click the Submit button.

NOTE: An administrator password must be created before a user password can be

created.

Resetting a password

Reset an existing password so that no password is required as follows:

1.

Clear any existing password.

2.

Enter a single space character in the

Password

and

Re-enter

Password

fields.

3.

Click the

Submit

button.

MTPX Plus Series • HTML Operation 132

Advertising