Signal Outputs

f

Outputs (MTP) connectors — Connect the TP inputs of compatible MTP or VTR

receivers to these RJ-45 female connectors.
See the Inputs connector (

item

a

) in the “Signal inputs” section, for detailed pin

assignments for the RJ-45 connectors.

CAUTION: Do not connect this device to a computer data or telecommunications

network.

NOTE: For best results, use a cable length of at least 25 feet (7.5 m) between the

TP output connector and the receiver.

g

Local Outputs (VGA) connector(s) — Connect one or two RGBHV video displays

to these 15-pin HD female connectors for each output.
Matrix sizes 1616 and smaller (excluding the MTPX Plus 128) have one local video
output.
Matrix sizes 1632 and larger and the MTPX Plus 128 have two local video outputs.
These outputs are always outputs 1 and 2, with the same inputs tied to them as to
TP outputs 1 and 2.

NOTES:

The video that is output on this (these) connector(s) is converted from

the tied proprietary TP input signal or the local (VGA) input. This feature
allows you duplicates of output(s) 1 (and 2) while eliminating the need
for extra receivers.

When either the output or input of a tie is local (VGA), Extron

recommends that the MTP input or output be connected by a minimum
of 25 feet (7.5 m) of TP cable to prevent overpeaking.

This connector can also output HD component video, component video,

S-video, or composite video, using the appropriate adapters, if that is
the video format that was input. See

figure 6

on page 13 to identify the

pins to use for the various video formats. Also, set the output to no sync
processing (see the

Local video output sync polarity

SIS commands on

page 83.