Rs-232 output inserts – Extron Electronics MTPX Plus Series User Guide User Manual

Page 21

Advertising
background image

RS-232 Output Inserts

e

RS-232 Output Insert connectors — For bidirectional RS-232 data that is routed

to a specific (unswitchable) TP output, connect a serial device to one of these 3.5 mm,
3-pole captive screw connectors. Figure 9 shows how to wire the connectors.

Receive (Rx)

Transmit (Tx)

Ground ( )

Bidirectional

RS-232

Device

Ground ( )

Receive (Rx)

Transmit (Tx)

Rx

Tx

Do not tin the wires!

Figure 9.

RS-232 Output Insert Wiring

CAUTION: The length of exposed wires is critical (see the

CAUTIONS

on page 14 for

details).

For the RS-232 Output Insert to be available on the TP output, the insert must be
enabled via an SIS command (see the “

Programming Guide

” section), the Matrix

Switchers Control Program (see the “

Matrix Software

“ section), or an MTPX Plus

HTML page (see the “

HTML Operation

” section).

Each RS-232 output insertion is dedicated to the output with that number; for example,
RS-232 Output Insert 1 is always routed to the Output 1 TP connector (when enabled
as described in the note above), RS-232 Output Insert 2 is routed to the Output 2 TP
connector, and so on.

NOTES:

When an RS-232 output insert is enabled, any content on the

audio/RS-232 wire pair for the TP input tied to that output is disabled.

The switch time for the RS-232 output insert is 50 ms.

MTPX Plus Series • Installation

15

Advertising