Extron Electronics MTPX Plus Series User Guide User Manual

Page 154

Advertising
background image

NOTE: The MTPX Plus switcher must be configured with the factory default IP

address (192.168.254.254) before the ARP command is executed, as
described below.

4.

At the PC, access the Command prompt (see “

Pinging to Determine the Extron IP

Address

” on the preceding page, steps 1 through 3), then enter the

arp –s

command.

Type in the desired new IP address for the unit (obtained in step 1) and the MAC address
of the unit (from the rear panel of the unit), for example

arp –s 10.13.197.7 00-05-A6-03-69-B0

and then press {Enter}.

The computer returns the command prompt (

C:\

).

After you issue the

arp -s

command, the controller changes to the new address and

starts responding to the ping requests to the new address, as described in the next step.

NOTE: You must ping the MTPX Plus switcher for the IP address change to take

place. The response should show the new IP address, as shown in

figure 92

.

5.

Execute a ping command by entering ping followed by a space and the new IP address
at the command prompt. For example:

ping 10.13.197.7

C:\>ping 10.13.197.7

Pinging 10.13.197.7 with 32 bytes of data:

Reply from 10.13.197.7: bytes=32 time<10ms TTL=128
Reply from 10.13.197.7: bytes=32 time<10ms TTL=128
Reply from 10.13.197.7: bytes=32 time<10ms TTL=128
Reply from 10.13.197.7: bytes=32 time<10ms TTL=128

Ping statistics for 10.13.197.7:
Packets: Sent = 4, Received = 4, Lost = 0 (0% loss),
Approximate round trip times in milli-seconds:
Minimum = 0ms, Maximum = 0ms, Average = 0ms

Figure 92.

Ping with New Address

NOTE: You can reconnect using either Telnet or a web browser to verify that the

update was successful.

6.

After verifying that the IP address change was successful, enter and issue the arp –d
command at the Command prompt. For example:

arp –d 10.13.197.7

removes 10.13.197.7 from the ARP table

or

arp –d*

removes all static IP addresses from the ARP table.

MTPX Plus Series • Ethernet Connection 148