Signal inputs, Mtpx plus series • installation 12 – Extron Electronics MTPX Plus Series User Guide User Manual

Page 18

Advertising
background image

Figure 4 shows the rear panel of the MTPX Plus 3232.

ETHERNET

ACT

INPUT

SELECT

LOCAL

RJ-45

LOCAL INPUTS

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

1

2

2

1

3

4

5

6

RS-232 OUTPUT INSERTION

LOCAL OUTPUTS

OUTPUTS

INPUTS

CONTROL

MONO AUDIO OUTPUTS

AUDIO INPUTS

LINK

RESET

L

R

1

L

R

2

L

R

3

L

R

4

L

R

5

L

R

6

L

R

1

L

R

2

L

R

3

L

R

4

L

R

5

L

R

6

L

R

7

L

R

8

Tx Rx

1

Tx Rx

2

Tx Rx

3

Tx Rx

4

Tx Rx

5

Tx Rx

6

Tx Rx

7

Tx Rx

8

Tx Rx

9

Tx Rx

10

Tx Rx

11

Tx Rx

12

Tx Rx

13

Tx Rx

14

Tx Rx

15

Tx Rx

16

US

LISTED

1T23
I.T.E.

®

3.2A MAX

4

INPUTS

13

11 12

10

4

2

1

7

3

8

5

3.2A MAX

6

Figure 4.

MTPX Plus 3232 Twisted Pair Matrix Switcher

NOTE: The MTPX Plus 1632 and MTPX Plus 3216 are housed in the same 3U enclosure,

but have fewer input connectors (16 x 32 matrix) or output connectors
(32 x 16 matrix) to accommodate their smaller matrix sizes.

CAUTIONS:

Use Electrostatic discharge (ESD) precautions (that is, be electrically

grounded) when making connections. Electrostatic discharge can damage
equipment, even if you cannot feel, see, or hear it.

Remove system power before making any connections.

Signal Inputs

a

Inputs (TP) connectors — Connect the TP outputs of compatible MTP or VTT

transmitters to these RJ-45 female connectors.

CAUTION: Do not connect this device to a computer data or telecommunications

network.

NOTES:

Configure the switcher for the appropriate content on the audio/RS-232

wire pair (pins 3 and 6) for each TP input (see “

Defining the Audio/

RS-232 Wire Pair

“ in the “Operation” section). You can also use

SIS commands (see the “

Programming Guide

” section), the Matrix

Switchers Control Program (see the “

Matrix Software

“ section), or the

HTML pages (see the “

HTML Operation

” section).

For best results, use a minimum cable length of at least 25 feet (7.5 m)

between the transmitter and the MTPX input and between the MTPX
output and the transmitter.

RJ-45 termination with CAT 5, CAT 5e, or CAT 6 cable must comply with

the TIA/EIA T568A or TIA/EIA T568B wiring standards for all connections.

RJ-45 termination with Enhanced Skew-Free A/V UTP cable must comply
with TIA/EIA T568A only.

For low resolution MTPs (S-video and composite video) on the TP

inputs, the MTPX Plus audio circuits are compatible only with the newer
generation, mono audio models. See your MTP transmitter/ receiver and
refer to the associated manual to determine which MTP models you have.

MTPX Plus Series • Installation