Using the command and response tables, Symbol definitions, Using the command/response tables – Extron Electronics MTPX Plus Series User Guide User Manual

Page 84

Advertising
background image

Using the Command and Response Tables

The command and response
table begins on

page 80

.

Symbols used in the
table represent variables in the
command and response fields.
Command and response examples
are shown throughout the table.
With the exception of the audio
input gain and attenuation
commands, the SIS commands are
not case sensitive. The ASCII to
HEX conversion table at right is for
use with the command and response table.

Symbol definitions

]

= Carriage return/line feed

}

= Carriage return (no line feed)

|

= Pipe (can be used interchangeably with the

}

character)

= space

E

= Escape key

W = Can be used interchangeable with the

E

character

X!

= Input number (for tie)

00 – (maximum number of inputs for your model) (00 = untied)

X@

= Output number

01 – (maximum number of outputs for your model)

X#

= TP input number

01 – (maximum number of TP inputs for your model)

X$

= Audio/RS-232 wire pair input type

0 = audio

1 = RS-232

X%

= RS-232 output insert port

MTPX Plus 128, 168, 816, 1616

01 – 08

MTPX Plus 1632, 3216, 3232

01 – 16

X^

= RS-232 output insert status

0 = disabled

1 = enabled

X&

= Input signal level/peaking range

000 – 255

X*

= Input number

01 – (maximum number of inputs for your model)

X(

= Threshold

0 = outside of threshold

1 = within threshold

X1)

= Skew adjustment range

00 – 31 (each step = 2ns)

X1!

= Video plane

0 = red

2 = blue

1 = green

X1@

= Pre-peakable output number

MTPX Plus 168

01 – 04

MTPX Plus 128, 816, 1616, 3216

01 – 08

MTPX Plus 1632, 3232

01 – 16

X1#

= Mute, pre-peaking, Lock mode, power supply

0 = off/mode 0/not OK

2 = mode 2

1 = on/mode 1/OK

X1$

= DDC value (EDID):

00 = Automatic

18 = 1366 x 768 @ 60 Hz

01 = Output 1

19 = 1400 x 1050 @ 50 Hz

02 = Output 2

20 = 1400 x 1050 @ 60 Hz

03 = 800 x 600 @ 50Hz

21 = 1440 X 900 @ 50 Hz

04 = 800 x 600 @ 60 Hz

22 = 1440 x 900 @ 60 Hz

05 = 1024 x 768 @ 50 Hz

23 = 1600 x 1200 @ 50 Hz

06 = 1024 x 768 @ 60 Hz

24 = 1600 x 1200 @ 60 Hz

07 = 1280 x 720 @ 50 Hz

25 = 1680 x 1050 @ 50 Hz

08 = 1280 x 720 @ 60 Hz

26 = 1680 x 1050 @ 60 Hz

09 = 1280 x 768 @ 50 Hz

27 = 1920 x 1080 @ 50 Hz

10 = 1280 x 768 @ 60 Hz

28 = 1920 x 1080 @ 60 Hz

11 = 1280 x 800 @ 50 Hz

29 = 1920 x 1200 @ 50 Hz

12 = 1280 x 800 @ 60 Hz

30 = 1920 x 1200 @ 60 Hz

13 = 1280 x 1024 @ 50 Hz

31 = User defined

14 = 1280 x 1024 @ 60 Hz

32 = User defined

15 = 1360 x 768 @ 50 Hz

33 = User defined

16 = 1360 x 768 @ 60 Hz

34 = User defined

17 = 1366 x 768 @ 50 Hz

ASCII to Hex Conversion Table