Serial Port Login Procedure

1.

From the Login: prompt, type

config

followed by the <Enter> key.

2.

When prompted for a password, type

config

followed by the <Enter> key.

The following menu will then appear.

Network Port 1

Network Port 2

==============

==============

0.

Speed/Duplex: auto_10_100_1000

10. Speed/Duplex: auto_10_100_1000

1. Boot method: static [dhcp]

11. Boot method: static [dhcp]

2. address: 192.168.0.1

12. address: 192.168.1.1

3. netmask: 255.255.255.0

13. netmask: 255.255.255.0

4.

gateway: 192.168.0.1

14

Gateway: 192.168.0.1

5. broadcast:

15. broadcast:

6.

mtu: 1500

16. mtu: 1500

7. controller ip: 192.168.0.18

17. ip forwarding: 0

8. controller port: 5432

18. webserver port: 80

9. Exit

3.

Type the menu option number required followed by the <Enter> key.

4.

Where required, type the new value followed by the <Enter> key.

5.

To exit the menu and return to the main command prompt, type

9

followed by the

<Enter> key.

Command options

The following commands are also supported from the main command prompt:

Exit

To logout from the session

Reboot

To force the VN 200 device to restart

Ping

To test network communications with another device (see

Understanding Network Performance

”)

VN-Matrix 200 Series • Technical Data