Extron Electronics VN-Matrix 200 Series User Manual

Page 94

Advertising
background image

Alarm Type Description - Encoder

Alarm Type

Description

Action

Default Settings

Encoder Alarm

No source

No source present at the input.

Check input connections;
is there an output on the
loop through connector?

Critical, reporting

Bad source syncs

Source is present, but
unrecognized ue to bad sync mea-
surement.

Critical, reporting

No SDI source lock

Applicable to VN 300, ignore for
VN 200.

Critical, reporting

Unsupported SDI
mode

Applicable to VN 300, ignore for
VN 200.

Critical, reporting

Unsupported mode

Source is present, mode not
supported.

Critical, reporting

Bad source

Critical, reporting

Analog phasing
error

Warning, reporting

Hardware encoding
error

The hardware is unable to encode
the input signal.

Critical, reporting

Unsupported audio
source

Critical, reporting

Data rate overload

The compressed data rate is too
high.

Increase the compression
or reduce the required bit
rate

Critical, reporting

Network overload

The network is dropping too many
packets.

Warning, reporting

VN-Matrix 200 Series • Alarms and SNMP

89