Ce. if it is not, see, Source, Checkup – Extron Electronics VN-Matrix 200 Series User Manual

Page 47: Source checkup

Advertising
background image

Source Checkup

When diagnosing problems with an encoder or source, it is highly recommended that
a local monitor be connected to the VNC 200. If a monitor is not already connected as
part of the system, it is suggested that one be connected temporarily. See the following
flowchart.

Is the local monitor completely blank

?

STAR

T

YES

NO

Check the POWER indicator on the VN

-MATRIX Encoder

...

UNLIT

LI

T

FLASHING

What’s the proble

m?

Check the STATUS indicator

on the Encoder

...

UNLIT

LI

T

FLASHING

NO POWE

R

Check the PSU connection to the VN-MATRI

X.

Check for ‘green’ light on PSU

.

Check mains cabl

e,

fuse and suppl

y.

POWER/THERMAL FAUL

T

The unit has shut down due to either a power supply fault or over temperature condition

.

Check for obstructed ventilation grilles,

excessive ambient

temperatur

e.

Cycle the power off and on to reset the uni

t.

If the problem recurs and ambient

temperature is within limits

, try using

a different PS

U.

NO SOURCE CONNECTED

/DETECTE

D

Follow the Controller Checkup

section and follow the checks listed

for ‘No Source Detected’.

SOURCE IS BEING STREAMED TO

ONE OR MORE DECODERS

This proves that the Encoder is

working OK

. If this source is not

being displayed on a particular

Decode

r, check that you have not

exceeded the limit of

4 RTP unicast

streams.

SOURCE OK BUT NOT BEING STREAMED

Follow the Controller Checkup

section

and check that all devices

are onlin

e.

If you have not already done so

, see

the Decoder Checkup.

Message Displayed… “No Source Detected

Source image is stable

but has a color cast

Source image is unstable or corrupte

d

Source image is badly framed

(black bars at

edges or edges croppe

d)

.

Check for loos

e/

incorrect connections or faulty cables between the source

and the Encoder

.

Check that the source is actually providing an output signal

(e.

g.

it may have

gone into a powe

r/screen saver mode

)

Check that the source type is supported and has been auto

-detected

correctly. If not

, try forcing the input to a manual source mode.

Check that an incompatible manual source mode has not been applied to

the input

. If so,

try setting the input to ‘auto’.

Check that the Encoder is not in ‘Standby’ mode.

Check for loos

e/

incorrect connections or faulty cables between the source

and the Encoder

.

Check that the source itself is actually stable

.

Check that the source type is supported and has been auto

-detected

correctly. If not

, try forcing the input to a manual source mode.

Check that an incompatible manual source mode has not been applied to

the input

. If so,

try setting the input to ‘auto’.

Try adjusting the clock phase settings. Check whether or not the source has Macrovision copy protection and set the Macrovision Defeat option accordingly.

Check that the correct color space as been applied to the source. Check for loos

e/

incorrect connections or faulty cables between the source

and the Encoder

.

Check that the original source itself is correctly framed

.

Try adjusting the Blanking settings on the Encoder.

VN-Matrix 200 Series • System Configuration

42

Advertising
This manual is related to the following products: