Alarms and SNMP

This section describes the following:

Overview – Alarms

Overview – SNMP

SNMP Trap Destinations

Overview – Alarms

The VN-Matrix system is configured to generate alarms for error conditions. A list of these
error conditions and their meanings are presented on the following pages.
Alarms can be monitored at a number of locations throughout the web GUI

In the Alarms page

In the list immediately below the Filter Settings box. This details the alarm
conditions that are currently active on the system.

In the Alarm Logs page

In the list immediately below the Filter Settings box. This provides a historical log
of when an alarm condition was raised and cleared.

In the Device List page

Where a traffic light system is used to represent the status of a device.

In the top left hand corner of each page in the web GUI.

Where the device status and system status is displayed.

In addition the red LED located on the front panel of the VN-Matrix device will illuminate
whenever a critical alarm is triggered.
Alarm conditions, once triggered, will remain active until the error that caused it has
cleared and then for an additional five seconds.