Is the target display completely blank

?

START

YES

NO

Check the POWER indicator on the VN

-MATRIX Decoder

...

UNLIT

LI

T

FLASHING

What’s the problem

?

Check the STATUS indicator

on the Encoder

...

UNLIT

FLASHING

NO POWE

R

Check the PSU connection to the VN-MATRIX Decoder

.

Check for ‘green’ light on the PSU

.

Check mains cabl

e,

fuse and supply

.

POWER/THERMAL FAUL

T

The unit has shut down due to either a power supply fault or over temperature condition

.

Check for obstructed ventilation grilles,

excessive ambient

temperatur

e.

Cycle the power off and on to reset the uni

t.

If the problem recurs and ambient temperature is within limit

s,

try

using

a different PSU

.

NO SOURCE SELECTE

D,

ENCODER

OFFLINE (Nodata Splash disabled

)

SOURCE DATASTREAM BEING RECEIVED

Check that the source is not outputting a ‘blank’ signal

.

Check that the display is powered and not in standby mode

.

Check for loos

e/

incorrect

connections or faulty cables between the Decoder and the displa

y.

If the display has multiple inputs

,

check that the correct input is

selected

.

If there are setup options for the display input

, check that these are

appropriate for the Decoder output format

.

Check that the display is compatible

with the Decoder output forma

t.

Message Displayed… “No Source Datastream

Source image is stable

but has a color cast

Source image is unstable or corrupted

Displayed image is

frozen

.

Check that the Decoder has a source selected

.

Check that the Decoder is not in disabled or standby mode.

Check that the corresponding Encoder device is operating and set up

correctly by following the Source Checkup.

Check for networ

k/

communication problems

.

Check for loos

e/

incorrect connections or faulty cables between the source

and the Encode

r.

Check that the visual disruption is not on the original source signal

.

Check to see if the Encoder local monitor has the same color cast

.

If so, check that the correct color space has been applied to the source.

Check for loos

e/

incorrect connections or faulty cables between the Decoder

and the displa

y.

Check that the original source itself is not frozen

.

If the source is OK

, the likely cause is that the source datastream has been

interrupted and the Nodata Splash option is disabled

. This will result in the

Decoder displaying the last valid source frame received

. Follow the checks

above for “No Source Datastream

”.

Message Displayed… “No Matching Output

Mode

The Decoder is receiving a data stream but is unable to find an output mode that matches the source forma

t. Most likely cause is that the Encoder is

using a custom input mode for which there is no matching output mode on the Decoder

. If this is the case you will need to create a custom output mode.

Image is stable but ‘drops

out’ (goes blac

k)

or

freezes intermittently

Check that the visual disruption is not on the original source signal

.

The image disruption could be caused by data packets being lost

. There

may be insufficient network bandwidth available resulting from high network

traffic or poor network performance

. Try increasing the compression settings

or adjusting the bandwidth limitation settings on the Encoder.

Displayed image is

noticeably poorer quality than the source

, either in

terms of clarity or refresh rate

.

The compressio

n/

bandwidth limitation settings on the Encoder may be set

too high

. Try decreasing the compression settings or adjusting the

bandwidth limitation settings on the Encoder.