4.4

Rectifiers (and Converters) Information (active area)

Tap this active area, located below Mode Status on the “home” page (Figure 2), to enter a new window of
operation for converter/rectifier updates and reports, see Figure 8 below:

Figure 8–Update (inventory) and report selection screen

4.4.1

Inventory Update

This button will enable the user to re-acquire all the attached modules to the CXC; to verify the existence of all
connected modules. Tap to evoke this command (and return to the home page).

A pop-up window (not shown here) will appear over the home page to show a progress bar of the number of
modules acquired during the update that has just been evoked. Tap the “X” button to clear the pop-up from the
active area.

Inventory update must be done whenever a module is removed from the system. The system is polled with
respect to the following scenarios:

 Module has failed and is no longer able to communicate, or
 User has removed a module from the system.

4.4.2

Rectifier Report (Converter Report similar)

This button (or menu item in 6.3.1) will enable the user to view, in a list (report), all of the acquired modules in the
system. Tap to evoke this command.

A new active area will be displayed, see Figure 9 below. The first column lists the serial numbers of the modules.
The report then displays the current output (A) of each module (or toggle for % of maximum output) and the
number of active alarms (if that module is issuing an alarm). The rightmost column displays the number of
settings out of tolerance (OOT per web interface).

Figure 9–Rectifier (or Converter) report screen

Rectifier (or Converter) Locate Feature — Once a module is selected, the (module) LED’s will start flashing.

Mode (+Temp Comp) display

Select operation here

Return to previous screen

Battery Volts and
Load Current display

FL + TC

54.00V 250A

Alarm Indication

Inventory Update

Rectifier Report

Converter Report

Select module to view details

Return to previous screen

FL + TC

54.00V 250A

Report headings for serial number,
current display (% or A), number of alarms
and settings out of tolerance (OOT)

Tap View Details to produce

a new window with pull-down menus

showing all of the alarms and settings

that are out of tolerance