Series 6A Operation & Maintenance – Technical Data

6A O & M : 38

Technical specifications

Add-on modules

Without Ex protection/

with Ex d protection

With Ex ia/ib protection

With Ex n/dust protection

SIA module

Limit transmitter with slot-type initiators

and alarm output

6DR4004-8G

(not for Ex d version)

6DR4004-6G

Limit transmitter A1, A2

2-wire connection

Ex protection

Without

II 2 G Ex ia/ib IIC T6

II 3 G Ex nA nL [nL] IIC T6

Connection

2-wire system to EN 60947-5-6 (NAMUR), for switching amplifier to be connected on load side

2 slot-type initiators

Type SJ2-SN

Function

NC (normally closed)

Connecting to circuits with the following

peak values

rated voltage 8 V

Current consumption:

≥ 3 mA (limit value not

responded)

≤ 1 mA (limit value

responded)

Intrinsically safe switching ampli-

fier EN 60947-5-6

U

i

= 15.5 V DC

I

i

= 25 mA

P

i

= 64 mW

at "nA" and "tD":

U

n

= 15.5 V DC

P

n

= 64 mW

at "nL":

U

i

= 15.5 V DC

I

i

= 25 mA

Internal capacitance C

i

41 nF

41 nF (at "nL")

Internal inductance L

i

100 μH

100 μH (at "nL")

Electrical isolation

The 3 outputs are electrically isolated from the basic device

Test voltage

840 V DC, 1 s

Alarm output
Connection

To switching amplifier according to EN 60947-5-6 (NAMUR), U

H

= 8.2 V, R

i

= 1 kΩ

Signal state High (not activated)

R = 1.1 kΩ

≥ 2.1 mA

Signal state Low (activated)

Ri = 10 kΩ

≤ 1.2 mA

Internal capacitance Ci

5.2 nF

5.2 nF (at "nL")

Internal inductance Li

Negligible

Power supply UH

U

H

≤ 35 V DC

I ≤ 20 mA

Connecting to circuits with the following

peak values

Intrinsically safe switching ampli-

fier acc. to EN 60947-5-6
U

i

= 15.5 V DC

I

i

= 25 mA

P

i

= 64 mW

at "nA" and "tD":

U

n

= 15.5 V DC

at "nL":

U

i

= 15.5 V DC

I

i

= 25 mA

Limit value contact module

Limit transmitter with mechanical ground

contact and alarm output

6DR4004-8K

(not for Ex d version)

6DR4004-6K

Limit transmitter A1, A2
Ex protection

Without

II 2 G Ex ia/ib IIC T6

II 3 G Ex nL [nL] IIC T6

Max. switching current AC/DC

4 A

Connection to intrinsically safe

circuit with maximum values:

U

i

= 30 V,

I

i

= 100 mA,

P

i

= 750 mW

Connection to circuits with maxi-

mum values:

at "nL":

U

i

= 30 V

I

i

= 100 mA,

Max. switching voltage AC/DC

250 V/24 V

30 V DC

30 V DC

Internal capacitance

Negligible

Negligible

Internal inductance

Negligible

Negligible

Electrical isolation

The 3 outputs are electrically isolated from the basic device

Test voltage

3150 V DC, 2 s

Alarm output
Connection

To switching amplifier according to EN 60947-5-6 (NAMUR), U

H

= 8.2 V, R

i

= 1 kΩ

Signal state High (not activated)

R = 1.1 kΩ

≥ 2.1 mA

Signal state Low (activated)

Ri = 10 kΩ

≤ 1.2 mA

Internal capacitance Ci

5.2 nF

5.2 nF (at "nL")

Internal inductance Li

Negligible

Power supply UH

U

H

≤ 35 V DC

I ≤ 20 mA

Connecting to circuits with the following

peak values

Intrinsically safe switching ampli-

fier acc. to EN 60947-5-6

U

i

= 15.5 V DC

I

i

= 25 mA

P

i

= 64 mW

at "nL":

U

i

= 15.5 V DC

I

i

= 25 mA