Assembly

Type 1062

D

J

E

H

Check that the seal "H" is fitted and
that it is correctly positioned inside
the actuator.

Insert the duplication system "D" into
the actuator.

Screw the duplication rod "E" onto
the actuator rod "J".

Tighten the adaptor until free contact
is obtained with the top of the
actuator, using a flat No 27 spanner.

E

Check that the seals have been fitted
and that they are undamaged. Replace
them if necessary.

Put thread lock into the internal thread
in the duplication rod "E".

F

G

Unscrew the small transparent cap "F"
on the actuator, preferably by hand or
using a suitable tool in order not to
damage it (except for actuators size
40mm).

Pump air into the actuator on a valve
which is normally closed (function "A")
or has a double effect (function "I") so
that the actuator rod moves to the top
position.

Unscrew the visual position feedback
"G" using a hexagonal male spanner.