Fitting the position feedback with stroke, Limiter to a pneumatic actuator size 50 to 80mm – Burkert Type 1062 User Manual

Page 19

Advertising
background image

19

Assembly

Type 1062

Fully tighten the duplication rod on
the actuator rod using a screwdriver
with a blade of suitable size.

Depressurize the actuator of a valve
which is normally closed (function
"A") or has a double effect (function
"I"): the valve recovers its default
position.

C
D

Insert the position feedback housing
into the duplication system "D"
setting the cable gland in the
direction desired and making sure,
on a mechanical contact version,
that you do not damage the contact
levers on the switches.

Fasten the housing and the dupli-
cation system by tightening the cone
point set screw "C" using a hex-
agonal male spanner.

K

L

Unscrew the cover "K" on the
position feedback.

Unscrew the cable gland "L".

Thread the cable through the cable
gland.

Wire according to the wiring
diagram for your version of the 1062:
See chap. „8 Installation and wiring“

.

Fasten the cable gland to ensure
tightness of the product.

7.4

fitting the position feedback with
stroke limiter to a pneumatic
actuator size 50 to 80mm

note

the tightness of the actuator is not guaranteed when the
transparent cap is removed.

▶ Prevent the projection of fluids into the actuator.
the tightness of the position feedback is not guaranteed
when the cover is removed.

▶ Prevent the projection of fluids into the position feedback.

english

Advertising