Wiring a version with double inductive 2-wire, Namur switch – Burkert Type 1062 User Manual

Page 32

Advertising
background image

32

Installationandwiring

Type 1062

+

-

A

+

-

200 mA max.

+ -

1062

10-30 VDC

500 mA

+

-

A

200 mA max.

+ -

Power supply

Load 1

Reaction speed according
to the max. load

Green light (valve open

detection)

Orange light
(voltage present)

Load 2

Valve open

switch

Valve closed
switch

Red light (valve closed
detection)

Fig. 15: Wiring a version with two inductive 3-wire switches in

PNP mode, valve open and valve closed detection

8.2.5 Wiring a version with double

inductive 2-wire nAmuR switch

Respect the maximum allowable characteristics of the circuit
established with an inductive NAMUR switch shown in the table
below.

Max.

authorised

ambient

Category

class

Ii

[mA]

(with

resistive

limit)

Pi

(mW)

U

(V)

Ci

(nF)

Li

(µH)

100 °C

II 2G

T4

60

200

20

180

350

85 °C

II 2G

T5

60

200

20

180

350

80 °C

II 2G

T5

60

200

20

180

350

70 °C

II 2G

T6

60

200

20

180

350

english

Advertising
This manual is related to the following products: