Assembly

Type 1062

D

Tighten the duplication
system "D" until free contact
is obtained with the top of
the limiter, using a flat No 27
spanner.

Fully tighten the duplication
rod on the actuator rod using
a screwdriver with a blade of
suitable size.

Depressurize the actuator of a
valve which is normally closed
(function "A") or has a double
effect (function "I"): the valve
recovers its default position.

C
D

Insert the position feedback
housing into the duplication
system "D" setting the
cable gland in the direction
desired and making sure, on
a mechanical contact version,
that you do not damage the
contact levers on the switches.

Fasten the housing and the
duplication system by tight-
ening the cone point set screw
"C" using a hexagonal male
spanner.

Q

R

Unscrew the cover "Q" on the
position feedback.

Unscrew the cable gland "R".

Thread the cable through the
cable gland.

Wire according to the wiring
diagram for your version of the
1062: See chap. „8 Installation
and wiring“.

Fasten the cable gland to
ensure tightness of the product.