Applications – Max Machinery 121 INDICATOR User Manual

Page 10

Advertising
background image

Pg 10

121-000-350 © 2001 Max Machinery, Inc.

Applications

3. Applications

3.1 Liquid Volume

Measurements:

A flowmeter measures the actual volume in a liquid line. A temperature sensor can also be installed to correct

for liquid thermal expansion (see 3.2 Corrected Volume).

Calculations:

• For Flowmeters with Pulse Outputs, Volume flow is calculated using the flowmeter

frequency output and the user entered K-Factor.

• For Flowmeters with Analog Transmitters, Volume flow is calculated using the measured

flowmeter signal and the user entered scale settings.

Output Results:

• Display Results

Flow Rate, Resettable Total, Non-Resettable Total

• Analog Output

Rate or Total

• Pulse Output

Total

• Relay Outputs

Rate or Total Alarms

Applications:

The Flow Computer can monitor actual volume flow and total of any liquid. Flow alarms are provided via
relays and datalogging is available via analog (4-20mA) and serial outputs.

Liquid Volume
Illustration

Calculations

Pulse Input; Average K-Factor

Volume Flow = input frequency • time scale factor

K-Factor

Analog Input; Linear

Volume Flow = % input • Full Scale Flow

Advertising