12. Glossary Of Terms

Acknowledge & Clear Alarms

Acknowledge is used to clear alarm relays and remove any visual alarm messages from the display. In the run mode, press
the ENTER key or activate CONTROL INPUT 3 (if set for ACK) to momentarily clear alarms and alarm messages. Alarms will
reassert themselves if alarm conditions are still present.

Analog Output

The analog signal (4-20mA) that is generated by the Model 121. It can correspond to the Rate, Total, Temperature or
Density. This output is used primarily for transmission of process information to remote systems.

Audit Trail

The audit trail is used to track the number of changes made to the units setup program.

Auto Batch Restart

The Auto Batch Restart function allows the user to set an amount of time to automatically restart a batch after the
completion of a batch. This time can be set from 1 to 99 seconds.

Batch Count Mode

Batch Count Mode specifies the user preference for count direction. The "Up" selection begins with a value of "0" and
counts up until the batch size is reached. The "Down" selection begins with a value equal to the desired batch size and
counts down to "0".

Batch Overrun

The Model 121 offers a batch overrun compensation routine. If batch overrun occurs due to slow valve response time, the
unit will compensate for the overrun amount on the next batch. This feature can be disabled if desired.

Batcher

An instrument which controls the dispensing of desired batch amounts. Liquid batching systems are usually comprised of a
batch controller (batcher), flowmeter and control valve. The batcher opens and closes the valve through the use of relays
and measures the amounts of liquid being dispensed via the flowmeter.

Baud Rate

The speed of serial communication transmissions, expressed in bits per second.

C-Factor (Fluid Expansion Factor)

A parameter in a flow equation which is used to describe the relationship between density or volume and temperature
changes.

Corrected Volume Flow

The equivalent volume at a reference temperature condition which involves the measurement of liquid volume flow using a
flow sensor and temperature sensor to compensate for thermal expansion.

Custody Transfer

Weights and Measure metering codes often specify several requirements for instruments and mechanisms to prevent and
track changes in the setup of an instrument which may be used in the commercial sale of goods. The Model 121 tracks
changes via the Audit Trail.

Data Logger

The capturing of information for printing out later use and the mechanism for specifying the conditions where a capture
should be made.

DC Output / Excitation Voltage

An on-board DC power supply used to power peripheral sensors. The Model 121 offers excitation voltages of 5VDC, 12VDC
or 24VDC when powered by AC voltage.

Default Value

The value to be used by the instrument if a sensor failure or out of range signal is detected.

Expansion Factor

See C-Factor

Flow Alarm

A visual indication that the volumetric flowrate is above or below the flow alarm setpoint specified by the user.