121-000-350 © 2001 Max Machinery, Inc.

Liquid Mass

3.3 Liquid Mass

Measurements:

Actual volume is measured by the flow element (DP transmitter, Flowmeter). Temperature

is measured by the temperature transmitter. A density transmitter can be used for direct
density measurements.

Calculations:

• The density and mass flow are calculated using the reference density and the thermal expansion coefficient of

the liquid (see "SET FLUID PROPERTIES" submenu)

Output Results:

• Display Results

Flow Rate, Resettable Total, Non-Resettable Total, Temperature, Density

• Analog Output

Rate, Total, Temperature or Density

• Pulse Output

Total

• Relay Outputs

Rate, Total or Temperature Alarms

Applications:

Monitoring mass flow and total of any liquid. Flow alarms are provided via relays and datalogging is available
via analog (4-20mA) and serial outputs.

Liquid Mass
Illustration

Volume Flow

As calculated in section 3.1

Mass Flow

Mass Flow = volume flow • density

Calculations