Max Machinery 121 INDICATOR User Manual

Page 26

Advertising
background image

ENTER

ENTER

ENTER

ENTER

ENTER

ENTER

ENTER

ENTER

ENTER

ENTER

ENTER

ENTER

ENTER

Pg 26

121-000-350 © 2001 Max Machinery, Inc.

6.4.8
SETUP
FLOW INPUT
(Pulse - Ain & PS
(A=B))

NOTE:
Ain = Single Pulse
PS(A=B) = Pulse

Security

Qx1 = Quadrature
Qx2 = Quadrature x 2

SETUP FLOW INPUT

EXCITATION VOLTAGE
5v 12v 24v

FLOW INPUT TYPE

Pulse

Analog

PULSE INPUT TYPE

Ain PS(A=B)

Qx1 Qx2

PULSE TRIGGER LEVEL
10mV 100mV 2.5V

LOW PASS FILTER
40Hz 3KHz 20KHz

INPUT TERMINATION
Pullup Pulldown None

MAX WINDOW (1-99)
1

K_FACTOR TYPE
Avg LinTbl UVC

AVERAGE KA-FACTOR
####### P/gal

LINEAR TABLE KA
Fre01:######## Hz

LINEAR TABLE KA
KA--01:####### P/gal

LOW FLOW RATE ALARM

####### gal/m

HIGH FLOW RATE ALARM
####### gal/m

Advance To

SETUP AUX INPUTS

Press ENTER to begin setup of Flow Input.

Select the desired Excitation Voltage.

Press ENTER when Pulse is flashing to configure
the flow input for Pulse signals.

Enter the desired Pulse type. See side note.

Select the desired Input Pulse Trigger Level.

Select the desired Low Pass Filter.
(Max. Count Speed).

Select the proper input termination.

Enter the desired Maximum Sample Window Time
(1-99 sec).

Enter the desired K-Factor Type.

If Avg selected, Enter the desired Average K-Factor.

If LinTbl selected,
Enter the desired frequency/ K-Factor pair for each
point in the Linearization Table.
NOTE: Enter 0 for Fre value of any point (other than

Fre01) to exit the routine and use the values
entered up to that point.

Enter the desired volumetric Low Rate Alarm.
This will trigger an alarm message if alarm condi-
tions occur. The relays are not affected.

Enter the desired volumetric High Rate Alarm.
This will trigger an alarm message if alarm condi-
tions occur. The relays are not affected.