Max Machinery 121 INDICATOR User Manual

Page 39

Advertising
background image

Principle Of Operation

121-000-350 © 2001 Max Machinery, Inc.

Pg 39

7.1 General:
General Operation

The 121 Series Flow Computer uses several internal calculations to compute the compensated flow based on
specific data input. Several computations are performed to arrive at the uncompensated flow, temperature,

density and viscosity. This information is then used to compute the Corrected Volume Flow or Mass Flow.

7.3 Flow Equations:

Input Flow Computation:

Linear or External SQRT
Input Flow = [% input span • (flow FS - flow low scale)]+ flow low scale

Input Flow Computation:

General Case
Tf = [% input span • (temp FS - Temp low scale)] + temp low scale

RTD Case
Tf = f(measured input resistance)

Input Density Computation:

Temperature Transmitter
density = reference density • (1 - Therm.Exp.Coef. • (Tf-Tref))

2

Density Transmitter
density = [% input span • (density FS - density low scale)] + density low scale

Uncompensated Flow Computation:

Pulse Input; Average K-Factor

Volume Flow = input frequency • time scale factor

K-Factor

Pulse Input; Linear Table

Volume Flow = input frequency • time scale factor

K-Factor (Hz)

Analog Input; Linear

Volume Flow = input flow

Analog Input; Linear Table

Volume Flow = input flow • correction factor (input flow)