Max Machinery 121 INDICATOR User Manual

Page 52

Advertising
background image

Pg 52

121-000-350 © 2001 Max Machinery, Inc.

MENU

ENTER

MENU

ENTER

MENU

ENTER

8.2.21
Pulse out test
Submenu Group

8.2.22
Relay test
Submenu Group

8.2.23
Control input test
Submenu Group

Pulse out test

Pulse out test
*0Hz 1Hz 10Hz 20Hz

Pulse out test

Relay Test

Rly1 Rly2 Rly3 Rly4

O ff Off Off Off

Relay Test

Control inputs test

TB1-9 TB1-10 TB1-11

Off Off Off

Control inputs test

Press Enter key to test the pulse output.

To simulate a frequency on the pulse output: Connect a frequenc
counter to (+)TB1-13,
(-)TB1-14. Press the key under the desired setting to move the
asterisk (*). The unit should output the selected frequency.

Press Menu key to return to Pulse out test top-level menu.

Press Enter to test the relays.

To manually control the relay outputs: Press the key under the
desired relay to toggle the relays On/Off. Use an ohmmeter to
check the relay contacts.

Press Menu key to return to Relay Test top-level menu.

Press Enter to test the control inputs.

To check the control inputs: Use TB1-12 as reference, input a DC
signal to TB1-9, TB1-10 and/or TB1-11, The Display will show O
when input is active, OFF when inactive.

Press Menu key to return to control input test top-level menu.

Advertising