Viewing OS6600-BPS-P Status

Installing and Managing Power over Ethernet (PoE)

page 3-4

OmniSwitch 6600 Family Hardware Users Guide

September 2006

Viewing OS6600-BPS-P Status

To view the current status of power supplies installed in the backup power supply, use the

show power

command as shown below.

-> show power 2

Power Supplies in chassis 2

PS Operational Status

-----+-------------------

PS-1

UP

PS-2

UP

The OS6600-BPS-P will always display as “PS-2”. For detailed information on show power command
output, refer to the CLI Command Reference Guide.