Power Supply Redundancy

After a backup power supply is installed, the primary (factory-installed) power supply continues to take on
the full power load for switch operations. Meanwhile, the backup power supply operates in active standby
mode. If the primary power supply fails unexpectedly, the backup power supply automatically takes up the
full power load without disrupting the switch.

OS6602-BPS Backup Power Supply Specifications

Input Voltage

85 to 150 VAC

Input Frequency

47 to 63 Hz

Efficiency

75% measured at 115 VAC

Temperature

Operating: 0 to +50 Celsius
Non-Operating: - 40 to +85 Celsius

Relative Humidity

5% to 90% Relative Humidity (Operating)
0% to 95% Relative Humidity (Storage)

Altitude

10,000 feet @ +32 Celsius

OS6602-BPS-DC Backup Power Supply Specifications

Input Voltage

36 to 72 VAC

Input Frequency

N/A

Efficiency

75% measured at 115 VAC

Temperature

Operating: 0 to +50 Celsius
Non-Operating: - 20 to +85 Celsius

Relative Humidity

5% to 90% Relative Humidity (Operating)
0% to 95% Relative Humidity (Storage)

Altitude

10,000 feet @ +32 Celsius

OS6600-BPS-P PoE Backup Power Supply Specifications

Width

15.50 inches, approx.

Height

2.61 inches, approx.

Height (rack units)

1.5 RU

Depth

4.53 inches, approx.

Ambient Temperature

0 to +70 deg C, operating;
-40 to +85 deg C, non-operating

Humidity

5% to 90% Relative Humidity (Operating)
0% to 95% Relative Humidity (Storage)

Altitude

10000 feet at +32 deg C, operating; 50000 feet, non-operating