background image

OmniSwitch 6600 Family Chassis and Hardware Components

Backup Power Supply

OmniSwitch 6600 Family Hardware Users Guide

September 2006

page 2-35

Viewing Power Supply Status for Stacked Configurations

When entering the show power command on the primary switch in a stacked configuration, you can either
enter only the show power syntax or you can specify a specific slot number. For more information, refer
to the examples below:

A Slot Number is Specified

If you specify a slot number after the command syntax, power supply information for only the correspond-
ing switch displays. For example:

-> show power 2

Power Supplies in chassis 2

PS Operational Status

-----+-------------------

PS-1 UP

PS-2 NOT PRESENT

In the example above, power supply status for the switch operating in slot 2 displays. No backup power
supply is installed in the slot 2 chassis (or the backup power supply is powered off).

No Slot Number is Specified

If you do not enter a slot number, power supply information for all switches in the stack displays. For
example:

-> show power

Power Supplies in chassis 1

PS Operational Status

-----+-------------------

PS-1 UP

PS-2 UP

Power Supplies in chassis 2

PS Operational Status

-----+-------------------

PS-1 UP

PS-2 NOT PRESENT

The example above shows the power supply status for a stack consisting of two switches. A backup power
supply is present and running in the switch operating in slot 1; no backup power supply is installed in the
switch operating in slot 2 (or the unit is powered off).