OmniSwitch 6600 Family Chassis and Hardware Components

Status LEDs

OmniSwitch 6600 Family Hardware Users Guide

September 2006

page 2-18

Status LEDs

LEDs provide visual status information. These “status lights” are used to indicate conditions such as
hardware and software status, primary and backup power supply status, primary and secondary status
(stacked configurations), temperature and fan errors, slot number information, link integrity, and data
flow. Refer to the diagram below for detailed information on OmniSwitch 6600 Family LED states.

Front Panel LED Descriptions (OS6648 Shown)

CONSOLE

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

1

2

EXPANSION/STACKING

EXPANSION

49

50

5 1

5 2

TM

OmniSwitch 6648

OK1

OK2

PS1

PS2

PRI

SEC

TEMP

FAN

27

28

29

30

31

32

33

34

35

36

37

38

39

40

41

42

43

44

45

46

47

48

25

26

LINK/ACT

LINK/ACT

LINK/ACT

LINK/ACT

SEL

45

47

Temperature Management
LEDs
TEMP.
Displays solid green
when the switch is operating
within the allowed temperature
range; displays solid amber if a
temperature error occurs (i.e.,
the switch is operating outside
the temperature range).

FAN. Displays solid green
when all fans in the fan tray
are running at normal speed.
Displays solid amber if a fan
error occurs (i.e., one or more
fans are not running at normal
speed).

Hardware and Software
Status LEDs
OK1.
Hardware Status. Dis-
plays solid green when pow-
ered on and the switch has
passed hardware diagnostic
tests. Displays solid amber
when powered on and the
switch has failed hardware
diagnostic tests.

OK2. Software Status. Blinks
green when the switch’s sys-
tem management software is
operational. Displays solid
amber when a system soft-
ware failure occurs. Blinks
amber when the software is in
a transitional state (e.g., when
software is being downloaded
to the switch).

Power Supply LEDs
PS1.
Displays solid green
when the primary (i.e., factory-
installed) power supply status
is OK and the power supply is
operating normally. Displays
solid amber in the unlikely
event of a power supply fail-
ure.

PS2. Displays solid green
when the optional redundant
power supply status is OK and
the power supply is operating
normally. Displays solid amber
if no redundant power supply
is installed or in the unlikely
event of a redundant power
supply failure.

Slot Indicator LED
The slot indicator LED is manually configurable
and displays the switch’s current slot number in a
stacked configuration (i.e., 1 – 8). For detailed
information on manually setting the switch’s slot
number, refer to

Chapter 4, “Managing

OmniSwitch 6600 Family Stacks.”

Ethernet Port LEDs
Each Ethernet port has a built-in corresponding status LED
on the lefthand side (OS6624, OS6648, OS6600-P24),
below the port OS6600-U24), or above the port (OS6602-
24 and OS6602-48). This LED indicates the link and activ-
ity status for each Ethernet port. The LED displays green
when a valid Ethernet cable connection exists. Flashes
green as data is transmitted or received on the port.
The OS6600-P24 only has a right-hand PoE LED. This
LED displays solid green when power is properly supplied
to the port. Flashes green when there is an overload or short.
And this LED is off if there is a power failure.

Status LED Location

Stack LEDs
PRI.
Displays solid green
when if the switch is either a
stand-alone switch or the pri-
mary switch in a stack; other-
wise, if the switch status is
secondary or idle, this LED is
off.

SEC. Displays solid green if
the switch is the secondary
switch in a stack; otherwise,
this LED is off.

Port Power LED
(OS6600-P24
only)

Advertising