Viewing fan status, Viewing fan status for stacked configurations, A slot number is specified – Alcatel-Lucent Omni 6600 User Manual

Page 80: Viewing fan status -56, Viewing fan status for stacked configurations -56, A slot number is specified - 56, For mor

Advertising
background image

OmniSwitch 6600 Family Chassis and Hardware Components

Temperature Management

OmniSwitch 6600 Family Hardware Users Guide

September 2006

page 2-56

Viewing Fan Status

The switch also constantly monitors fan operation. If any of the three fans unexpectedly shuts down, the
switch sends out a trap to the user and the FAN LED on the chassis front panel displays amber.

Note. For detailed LED information, including the FAN LED, refer to

“Status LEDs” on page 2-18

.

To check the current fan status, use the show fan command. For example:

-> show fan

Chassis Fan Status

-------+---+-----------

1 1 Running

1 2 Running

1 3 Running

In the example above, all three fans are operating normally.

Viewing Fan Status for Stacked Configurations

When entering the show fan command on the primary switch in a stacked configuration, you can either
enter only the show fan syntax or you can specify a specific slot number. For more information, refer to
the examples below:

A Slot Number is Specified

If you specify a slot number after the command syntax, fan status information for only the corresponding
switch displays. For example:

-> show fan
Chassis Fan Status
-------+---+-----------
1 1 Running
1 2 Running
1 3 Running

In the example above, fan status displays only for the switch operating in slot 3.