Setting the capacitor detection method, Setting the capacitor detection method - 8 – Alcatel-Lucent Omni 6600 User Manual

Page 104

Advertising
background image

Configuring Power over Ethernet Parameters

Installing and Managing Power over Ethernet (PoE)

page 3-8

OmniSwitch 6600 Family Hardware Users Guide

September 2006

Setting the Capacitor Detection Method

By default, the PowerDsine capacitor detection method is disabled on the OmniSwitch 6600-P24. To
enable it use the

lanpower capacitor-detection

command by entering lanpower capacitor-detection

followed by the slot number of the OmniSwitch 6600-P24 and enable.

For example, to enable the capacitor detection method on the OS6600-P24 with slot number 2 enter:

-> lanpower capacitor-detection 2 enable

To disable it use the

lanpower capacitor-detection

command by entering lanpower capacitor-detection

followed by the slot number of the OS6600-P24 and disable.

For example, to disable the capacitor detection method on the OS6600-P24 with slot number 2 enter:

-> lanpower capacitor-detection 2 disable

Note. The capacitive detection method should only be enabled support legacy IP phones only—this feature
is not compatible with IEEE specification 802.3af. Please contact your Alcatel sales engineer or Customer
Support representative to find out which Alcatel IP phones models need capacitive detection enabled.