Priority disconnect is disabled, Monitoring power over ethernet via the cli, Priority disconnect is disabled - 11 – Alcatel-Lucent Omni 6600 User Manual

Page 107: Monitoring power over ethernet via the cli -11

Advertising
background image

Installing and Managing Power over Ethernet (PoE)

Monitoring Power over Ethernet via the CLI

OmniSwitch 6600 Family Hardware Users Guide

September 2006

page 3-11

Priority Disconnect is Disabled

Reminder. Priority disconnect examples are only applicable when there is inadequate power remaining to
power an incoming device.

When priority disconnect is disabled, power will be denied to any incoming PD, regardless of its port
priority status (i.e., low, high, and critical) or physical port number (i.e., 1–24).

Monitoring Power over Ethernet via the CLI

To monitor current PoE statistics and settings, use the

show lanpower

command. The command output

displays a list of all current PoE-capable ports, along with the following information for each port:

Maximum power allocated to the port, in milliwatts

Actual power used by the port

Current port status

Power priority status

Power on/off status

Aggregate slot and chassis management information also displays. This information includes:

Maximum watts allocated to the corresponding slot

Amount of power budget remaining that can be allocated for PoE modules

Total amount of power remaining that can be allocated for additional switch functions

Advertising