3-7 Wiring

Built-In Transistor I/O Chips: Output Wiring, Sourcing

The output power supplies shown can be internal to the
load device being driven. This will normally be the case
when connecting to PLC's.

The loads connected to outputs 1-8 must all be powered
from the same power supply.

The loads connected to outputs 9-16 must all be powered
from the same power supply.

The same power supply can be used to power all 16 outputs
by paralleling the wiring between the “+” and “-” terminals
on the PL

µ

S output terminal strips.

The load power supply must be connected to both the “+”
and “-” terminals on the output terminal strip(s).

The unpluggable output terminal strips are keyed so they
can only be plugged into the correct receptacle.

Use shielded cable(s) for output wiring. Electro Cam 10
conductor cable part number PS-4300-04-XXX (XXX=length
in feet) is recommended. Two cables required for 16 output
units.