Electro Cam 5000 Series User Manual

Page 20

Advertising
background image

3-8 Wiring

Built-In Transistor I/O Chips: Output Wiring, Sinking

The output power supplies shown can be internal to the load
device being driven. This will normally be the case when
connecting to PLC's.

More than 1 power supply can be used to power loads within
each group of 8 outputs. Only one of the power supplies
used within the group can have its positive side connected
to the “+” terminal of the corresponding 5011 output terminal
strip. The common of each power supply used within a
group of 8 outputs must be connected to the “-” terminal of
the output terminal strip.

The same power supply can be used to power all 16 outputs
by paralleling the wiring between the “+” and “-” terminals on
the 5011 output terminal strips.

Both the “+” and “-” terminals on the output terminal strip(s)
must be connected to a load power supply.

The unpluggable output terminal strips are keyed so they
can only be plugged into the correct receptacle. Do not force
when plugging them in.

Use shielded cable(s) for output wiring. Electro Cam 10
conductor cable part# PS-4300-XXX (XXX=length in feet) is
recommended. Two cables required for 16 output units.

PS-5011
PS-5111

Advertising