4-8 Programming, Standard Features

FCN 7 - Motion ANDing of Output Channels

(Master Program Enable Input MUST be energized)

This function selects which output channels will be ANDed
with the Motion setpoints as programmed in FCN 1. ANDed
outputs will be on during their programmed pulses only if the
RPM is within the Motion setpoints. In order for Motion
ANDing to take affect, “On” and “Off” pulses must be
programmed into the selected channel.

An output channel can be turned into a motion detector by
programming it to be “On” at 1, “Off” at 1, and then ANDing
it with the Motion setpoints. Setting both points at 1 will turn
the output on for a full 360

°

. By ANDing this output to the

Motion setpoints, the output will be on constantly as long as
the RPM is within the Motion setpoint range.

on - Output is disabled IF present RPM is not within Motion
setpoints.

oFF - Output will cycle on and off at programmed position
setpoints regardless of present RPM.

Present Motion ANDing
status shown for output
selected

2nd

Press CHN key
to select output #

1st If FCN 7
not shown press:

FCN 7 ENT

Present output

channel

selected

3rd

Press PULSE key to select
between on and oFF

Note: Once programmed in a channel, this function will be present in that channel in all programs.