Resolver wiring and dimensions, 14 wiring, Resolver dimensions – Electro Cam 5000 Series User Manual

Page 26: Standard resolver cables

Advertising
background image

3-14 Wiring

RESOLVER DIMENSIONS

Resolver Wiring and Dimensions

Shield

Red

Green

Black

Black

White

Black

Pin A - Black

Pin D - Red

Pin E - Black

Pin F - White

Pin B - Green

Pin C - Black

Cable Type:
3 individually shielded pairs, 22 gauge

Shield

(see note below)

Front View

(pin out)

= Not Used

Shielding Note: Resolver cables made after 3-2-93 have a ring lug on a black shield wire at
the resolver end. The ring lug should be attached to one of the resolver connector strain relief
screws to protect against static discharge through the resolver cable. In some installations, it
may be advisable to disconnect the ring lug to prevent ground loops through the cable shield.
Consult Electro Cam if electrical noise problems are suspected.

Shield

Connector - Resolver End
PT# PS-5300-01-MSC
(ITT Cannon # KPT-06-F-12-10-S)

Connector - Controller End
PT# PS-5300-01-TER
(Weidmuller # BLA7 12822.6)

STANDARD RESOLVER CABLES

PT# PS-5300-01-XXX (XXX = LENGTH IN FEET)

S2

S4

S1

S3

R1

R2

Flange Mount Resolver - 3/8" Shaft

Foot Mount Resolver - 3/4" Shaft

0.375/
0.374"
9.53/
9.50 mm

0.749/
0.747"
19.02/
18.97 mm

With Rear Connector (shown):

PS-5238-11-ADR

With Side Connector:

PS-5238-11-ADS

Cable:

PS-5300-01-XXX where “XXX” is length in feet.

With Rear Connector (shown):

PS-5275-11-ADR

With Side Connector:

PS-5275-11-ADS

Cable:

PS-5300-01-XXX where “XXX” is length in feet.