Output setpoint programming, 3 programming, standard features, Create setpoints clear setpoints – Electro Cam 5000 Series User Manual

Page 31: Select output channel, 16 view setpoints, Clear 1 pulse, Clear existing setpoints, Multi-pulse mode pulse mode, Change setpoints, Inc/dec numeric entry

Advertising
background image

4-3 Programming, Standard Features

Note: When entering multiple pulses, press

ENT

after each

CREATE SETPOINTS

CLEAR SETPOINTS

Output Setpoint Programming

Programming Error Messages

Flashing error messages indicate programming mistakes
as they occur.

Simply press to cancel flashing error message.

POS

CHN

PGM

FCN

CLR

If POS or RPM
led NOT lit press:

POS or RPM
led now lit

SELECT OUTPUT CHANNEL

POS
RPM

CHN

1

6

VIEW SETPOINTS

View setpoints of output channel presently selected.

E1 OLAP: Output pulse just attempted overlapped an existing output

pulse on same channel.

E2 -run:

Attempted programming can NOT be done while machine is
running (transducer is turning).

E4 -Pro:

Program enable Off when programming was attempted.

E5 8888:

Value entered NOT valid for item being programmed.

E6 -379:

Invalid setpoint entered: A setpoint ending in 3, 7, or 9 was
entered. (Encoder Only - Exceptions: 89, 179, 269, and 359)

E7 -dEF:

Attempted to program too many Enable Inputs (FCN 9).

E9-tdE:

Attempted to program too many timed outputs (FCN 5).

E11-ScE:

Attempted to program more than 16 speed compensated
outputs (48 I/O controls only).

See pgs. A-12 thru A-14 for more details on error messages.

Output Setpoint Programming

Desired output channel MUST be selected before its
setpoints can be created, viewed, adjusted, or cleared.

CHN and POS
displays blank

1st Digit shown
in CHN display

2 Digit value in
CHN display

ON/OFF setpoints shown in position
display in increasing order with ON
and OFF LEDs. 0 is shown and both
LEDs off if no setpoints exist.

ON/OFF setpoints shown in position
display in decreasing order with ON
and OFF LEDs. 0 is shown and both
LEDs off if no setpoints exist.

VIEW

VIEW

VIEW

VIEW

Channel 16 used as example.

CLEAR 1 PULSE

To clear 1 pulse (1 pair of setpoints) on selected output channel.

Use numeric entry method (shown in CHANGE SET-
POINTS above) to set OFF setpoint equal to ON setpoint
value. Both setpoints will be erased.

To clear all setpoints on selected output channel.

CLEAR EXISTING SETPOINTS

ON Led lit,
POS blanks

ON

OFF

0 shown in
POS display

0 shown in
POS
display

OFF Led
lit, POS
blanks

ENT

POS display
blinks and
shows 0, ON
and OFF LEDs
are off.

0

0

To change all setpoints in the output channel simultaneously.

MULTI-PULSE MODE

PULSE MODE

To change both setpoints of a pulse simultaneously.

CHANGE SETPOINTS

Pulse led lit

OR

INC/DEC

NUMERIC ENTRY

To change setpoints in output channel presently selected.

PULSE

INC

DEC

PULSE

INC

DEC

INC

DEC

Displayed ON/OFF setpoint increases 1
increment each time INC key is pressed.

Displayed ON/OFF setpoint decreases 1
increment each time DEC key is pressed.

5

1st Digit shown in
POS display

0

2 Digits shown in
POS display

ENT

POS display blinks once to
confirm setpoint change.

Changing setpoint to 50 degrees used as example.

ON and OFF setpoints of ALL pulses

increase/decrease 1 increment each

time INC/DEC key is pressed.

ON and OFF setpoints of ALL pulses

increase/decrease 1 increment each

time INC/DEC key is pressed.

DEC

INC

OR

Pulse led lit

PULSE

Pulse led
blinking

1st Digit shown in
POS display

OFF led lit, POS
blank

POS display blinks
once to confirm
setpoint entry.

2 Digits shown in
POS display

1st Digit shown in
POS display

2 Digits shown in
POS display

On led lit, POS
blank

ON

3

0

OFF

6

0

ENT

On at 30 degrees used as example.

Off at 60 degrees used as example.

To create setpoints in output channel presently selected.

pulse.

Advertising