4-6 Programming, Standard Features

2nd

Press CHN key to
select rU

3rd

Press PULSE key to select
desired update frequency.

1st If FCN 0
not shown press:

FCN 0 ENT

rU

rPM Update

selected

Viewing / Changing Program Banks

Present rPM Update
frequency shown

Comm Item

Choices

ct (port type)

RS-232, RS-485

cS (baud)

4800, 9600, 19200, 38400

cA (comm add)

0-255; 1 is default

2nd

Press CHN key
to choose ct, cS, or
cA

3rd

Press PULSE key to select
desired option when ct or cS are
selected

When cA is selected press
number keys followed by ENT
to change comm address

1st If FCN 0
not shown press:

FCN 0 ENT

ct - comm type

cS - comm speed

cA - comm Address

Present value for
selected comm
item selected

Default settings are shown in bold face.

ct, cS, cA - Communication Parameters

ct - communication type: Specifies the type of
communication port being used by the PL

µ

S control. It

contains both an RS-232 and an RS-485 port. RS-485 is
the default setting.
Both of these ports share the DB-9
connector located at the top of the power supply section.
The type of port being used on the PL

µ

S must match the

type of port being used by the device communicating with
the PL

µ

S.

cS - communication Speed: Specifies the baud rate (bits
per second) that the PL

µ

S communication port will operate

at. It must be set for the same baud rate as the device
communicating with the PL

µ

S control. The choices are:

4800, 9600, 19200, and 38400 baud. 9600 is the default
setting.

cA - communication Address: Each control can have
a unique communication address (0-255) because multiple
controls can be wired to the same host device in a RS-485
network. This allows the host to send information to a
specific control while the other controls will ignore the
information. A PL

µ

S control will ignore incoming information

if the address that information specifies does not match the
communication address of the control.

rU - rPM Display Update Frequency

This function determines the frequency with which the
display of RPM is updated.

1 Display updates RPM once per second
2 Display updates RPM twice per second

10 Display updates RPM ten times per second

NOTE: On units manufactured prior to date code 9740,
the Expanded Operator Access (-E) option was required
for rPM Display Update Frequency (rU).

NOTE: On units manufactured prior to date code 9740,
the Communications Parameters (-C) option was
required for communications features.