4-9 Programming, Standard Features

Master Level Programming, PS-5XX4 Only: FCN 8 & FCN 9

Programming the Number of Enable Inputs

3rd

Enable Input #

Selected

1st If FCN 9
not shown press:

FCN 9 ENT

Present Enable
Mode of Selected
Enable Input

Press number key followed by
ENT to change Enable Mode of
Enable Input selected

Number of

Enable

Inputs

Press CHN key to
select Enable Input

2nd

Programming Output Enable Modes

Present Enable Mode
of Enable input

2nd

Press PGM key
(number of Enable
Inputs blinks)

3rd

Press number key followed by
ENT to change number of
Enable Inputs

1st If FCN 9
not shown press:

FCN 9 ENT

Present

number of

Enable Inputs

FCN 9 - Enable Inputs and Enable Modes

(Master Program Enable Input MUST be Energized)

The number of Enable Inputs and the mode of operation for
each output group with an Enable input is determined by
FCN 9.

The 1st Enable Input (Output Group Enable 1) is located on
the Logic terminal strip. If additional Enable Inputs are
programmed, they will be input modules on the I/O rack,
starting in order from the first module position (Group 2
Enable: module position 1; Group 3 Enable: module position
2; etc.). Each additional Enable Input reduces the available
outputs by one, and automatically reduces the last output
group by one output.

Brief Summary of Enable Modes:

Mode 0 - Normal PLS operation, no Enable Input.
Mode 1 - Enable Input causes Group position to re-zero.
Mode 2 - Enable Input causes Group position to re-zero

and enables outputs to cycle during next
revolution.

Mode 3 - Group outputs are on only if Enable Input is on.
Mode 4 - Enable Input (within enable window) enables

outputs to cycle during next revolution; group
position does not re-zero.

Modes 1, 2, and 4 require enable windows to be programmed.
Channel 91 is enable window for Group 1, channel 92 for
Group 2 and etc. See Enable Modes in appendix for details.

Present number of
outputs

2nd

Press PGM key
(Number of Output
Groups blinks)

3rd

Press number key followed by
ENT to change number of output
groups (1-8)

1st If FCN 8
not shown press:

FCN 8 ENT

Present

number of

Output Groups

3rd

Output Group

# selected

1st If FCN 8
not shown press:

FCN 8 ENT

Present number of
outputs in selected
Output Group

Press number key followed by
ENT to change number of
outputs in selected group

Number of

Output

Groups

Press CHN key to
select Output Group #

2nd

Programming the Number of Output Groups

Programming the Number of Outputs in Each Group

FCN 8 - Subdividing Outputs into Groups

(Master Program Enable Input MUST be Energized)

The outputs can be subdivided into as many as eight output
groups. The number of output groups and the number of
outputs in each group is determined by FCN 8.

Each output group can be set at a unique degree position
through FCN 2 (CHN key selects Output group #).

When more than one output group exists the POS/RPM key
will individually display each group's position by showing
the group number above the CHN key while showing the
current position next to the POS/RPM key.

When the number of outputs in each group is being assigned,
all of the outputs must be accounted for. The last output
group will automatically contain the outputs remaining after
the number of outputs in the other groups is defined. The
number of outputs in the last group automatically changes
if the total number of outputs in the other groups is changed.

Each output group can have a dedicated enable input and
be assigned to operated in any one of the Output Enable
Modes. See FCN 9 for programming Enable Inputs and
Modes.

See Output Grouping and Enable Modes section in the
appendix of this manual for further information on output
grouping.

Note: Once programmed in a channel, this function will
be present in that channel in all programs.