Ps-5x34 system: wiring to plc's, 12 wiring, Ps-5x34 system: wiring to plcs – Electro Cam 5000 Series User Manual

Page 24

Advertising
background image

3-12 Wiring

PS-4100-12-N32

Wiring to a PLC with Sinking Inputs

(A.B. calls these Sourcing Inputs)

Power Supply can be
external from the PLC

Note:

PL

µ

S transistor output

rack and PLC MUST
both be connected to
the same DC positive.

PLC

Wiring to a PLC with Sourcing Inputs

(A.B. calls these Sinking Inputs)

Power Supply can be
external from the PLC

PS-4100-12-P32

Note:

PL

µ

S transistor output

rack and PLC MUST
both be connected to
the same DC common.

PLC

PS-5X34 System: Wiring to PLCs

Advertising