4-1 Programming, Standard Features

Levels of Programming Access

The 5000 Series of controls have three levels of programming
access. Entry into these levels of programming is
accomplished through dedicated hardware inputs and/or
programmable enable codes entered through the keyboard.

Master Level—Accesses all programmable features. In
addition to all setpoints and functions, the Master Level also
establishes the keyboard entry codes for the “Setup” and
“Operator” access levels. Master Level programming also
determines which outputs are accessible to the operator.

NOTE: On units prior to date code 9740, operator access
was limited to setpoints and timed output values, unless
equipped with the Expanded Operator Access (-E) option.

Setup Level—Accesses all output setpoints and the
functions listed on the keyboard. These are control aspects
that may need occasional adjustment, but go beyond normal
operator responsibilities.

Operator Level—Functions available as specified in Master
Level programming. The operator is allowed to change the
following settings for output channels designated in FCN 6:

• Setpoints

• Offset

• Timeouts

• Active Program Number

• Motion Detection Settings

• Speed Comp Settings

Master Programming is enabled when terminal 6 is connected
to terminal 1 or 2. The Master Level can only be accessed by
energizing this input.

Hardware Program Enable Circuits

Logic Terminal Strip

Operator Programming is enabled when terminal 9 is connected
to terminal 1 or 2. The Operator Level can also be accessed
through a keyboard enable code.

Keyboard Enable Codes for Setup and Operator Access

Programming Access Levels

LOGIC COMMON

PROGRAM SELECT 2

PROGRAM SELECT 3

MASTER PROGRAM ENABLE

OPERATOR PROGRAM ENABLE

MOTION DETECTION OUTPUT

OUTPUT GROUP ENABLE 1

+12VDC OUT - 150 mA MAX

1

2

3

4

5

6

7

8

9

10

PROGRAM SELECT 1

FEATURE

MASTER

SET UP

OPERATOR

Enable Method

hardware

code

hardware / code

Output Set Points

All

All

Selected

Output Time Out Values All

All

Selected

Motion Set Points

Yes

Yes

Selected

Offset

Yes

Yes

Selected

Active Program

Yes

Yes

Selected

Speed Compensation

Yes

Yes

Selected

Direction of Rotation

Yes

No

No

Scale Factor

Yes

No

No

Set Up Enable Code

Yes

No

No

Operator Enable Code

Yes

No

No

Time Base Selection

Yes

No

No

Motion ANDed Outputs

Yes

No

No

Select Operator Outputs Yes

No

No

Output Enable Modes

Yes

No

No

OPTIONAL FEATURES:
Lead/Trail Speed Comp

Yes

No

No

Communication Setup

Yes

No

No

Analog Setup

Yes

Yes

Selected

The table below details which functions and set points can
be changed at the three levels of programming access. It
also indicates if the programming access levels can be
accessed by hardware input and/or keyboard enable code.

Either the Setup or Operator programming levels can be accessed by
entering the corresponding program enable code through the keyboard.
These codes can be 1, 2, 3, or 4 digit numbers and are established
during Master Level programming.

To Enter a program enable code number press:

FCN 0 ENT 1st digit 2nd digit 3rd digit 4th digit ENT

The PE codE message will disappear when a valid enable code is
entered.

The level of access gained depends upon which code number is
entered.

Programming access will time-out approximately 5 minutes after the
last keystroke. To cancel access before the 5 minute time-out press:

FCN 0 ENT CLR/CLE ENT

Advertising