4-7 Programming, Standard Features

Master Level Programming, Standard Controls: FCN 6 & FCN 7

FCN 6 - Operator Access

(Master Program Enable Input MUST be energized)

This function selects which features can be adjusted at
the Operator access level. Step through them one at a
time, and select On or Off according to whether or not
the Operator should be able to adjust them.

Functions that are not Channel-Specific:

Sd—Speed Detection (FCN 1, Motion Setpoints and Analog
Parameters if control has the “-A” option)

on

Operator can adjust FCN 1 values

oFF Operator cannot adjust FCN 1 values

oF—Offset (FCN 2)

on

Operator can adjust offset values

oFF Operator cannot adjust offset values

AP—Active Program (FCN 3)

on

Operator can change program number

oFF Operator cannot change program number

Functions that are Channel-Specific:

The following functions—“SP,” “Sc,” and “to”—will be
adjustable only for those channels turned “on“ through
“Output Channel Selection.”

Output Channel Selection

on

Operator can adjust values in this channel

oFF Operator cannot adjust values in this channel

SP—Setpoints

on

Operator can adjust setpoints

oFF Operator cannot adjust setpoints

Sc—Speed Compensation (FCN 4)

on

Operator can adjust speed comp values

oFF Operator cannot adjust comp values

(Encoder-based controls with the “-E” option have
Negative Speed Compensation capabilities, page 4-9.)

to—Timed Outputs (FCN 5)

on

Operator can adjust timed outputs

oFF Operator cannot adjust timed outputs

2nd

Press CHN key
to select Output
Channel

1st If FCN 6
not shown press:

FCN 6 ENT

Output

Channel
selected

Setting Output Channel Access

Operator Enable status
shown for selected
output channel

3rd

Press PULSE key to toggle
Enable Status on and off

2nd

Press CHN key
to select function

1st If FCN 6
not shown press:

FCN 6 ENT

SP, Sd, oF,

AP, Sc, or to

selected

Setting Operator Accessible Functions

Operator Enable status
shown for selected
function

3rd

Press PULSE key to toggle
Enable Status on and off

NOTE: On units manufactured prior to date code 9740,
operator access was limited to setpoints and timed
ouput values, unless equipped with the Expanded
Operator Access (-E) option.