4-11 Programming, Standard Features

Present Program
number shown

2nd

Press CHN key
to select Pn

3rd

Press number keys followed by
ENT to change active Program
number. (1-64 are valid Program
numbers)

1st If FCN 3
not shown press:

FCN 3 ENT

Pn

Program

number

Viewing/Changing Program Number

Present Program Bank
number shown

2nd

Press CHN key
to select Pb

3rd

Press number keys followed by
ENT to change Program Bank

1st If FCN 3
not shown press:

FCN 3 ENT

Pb

Program

bank

Viewing/Changing Program Banks

Present Active Program
number shown

2nd

Press CHN key
to select AP

3rd

Press 1 key followed by
ENT to change active Pro-
gram to 1.

1st If FCN 3
not shown press:

FCN 3 ENT

AP

Active

Program

Viewing/Changing the Active Program

If the hardware program select inputs are going to be used
to select programs (they can be driven from a PLC or
selector switch), it may be necessary to program the Program
bank (Pb) and Active Program (AP) from the keyboard.
Follow the instructions given below under “Hardware
Selection of Program Number.”

Viewing or Changing Active Program Number from
Keyboard

Use the Program number (Pn) feature of FCN 3 to see the
active program number or select any program directly by
entering the corresponding number from 1-64. The
corresponding “Pb” and “AP” values will automatically be
calculated and selected. It will not be necessary to calculate
or program “Pb” or “AP”, but they can be viewed to verify that
their values correspond to the selected program number.

Pn— Program number (1-64)
Pb— Program bank (1-8); 8 banks of 8 programs each
AP— Active Program (1-8); active program within bank

Example:

If Program number (Pn) 34 is selected, “Pb” will equal five
(5th bank of eight programs) and “AP” will equal two (2nd
program within this bank).

DO NOT enter values into “Pb” or “AP” if the keyboard
program selection is being used. Simply program “Pn” to the
desired program number from 1-64.

Hardware Selection of Program Number

The hardware program select inputs override the keyboard
programmed Active Program (AP) value when any one or
combination of the inputs is energized. When the hardware
inputs are used to select the Active Program (AP), insure
that “AP” is set equal to one.

The hardware select inputs only affect the current “AP”
value that is controlling the outputs. The “Pb” is not affected
by the select inputs and has to be changed from the
keyboard if more than eight programs are used.

To summarize, hardware select inputs can select which of
the eight programs in the current program bank is controlling
the outputs, but changing the program bank number must
be done through the keyboard by programming “Pb.”

Note: Active Program and Program Bank can be changed
through the serial communication port also.

Setup Level Programming, Standard Controls: FCN 1, FCN 2, FCN 3