Transducer Specifications

ENCODER(S)

Operating Temp:

0

°

to 50

°

C (32

°

to 122

°

F)

Storage Temp:

-40

°

to 50

°

C (-40

°

to 122

°

F)

Operating Humidity:

95% Relative non-condensing

NEMA Rating:

NEMA 12 (PS-4256, 4257)
NEMA 4X (PS-4456, 4457)

Max Cable Length:

1000 Ft.

Enclosure Size:

6"W x 6"L x 4.25"H

Mounting Holes (4):

5/16" Diameter

Weight:

9 Lbs.

Shaft Diameter:

.75" (double ended) with
Woodruff keyway #606

Maximum RPM:

1000 RPM (PS-4256, 4456)
2000 RPM (PS-4257, 4457)

Resolution:

8 Bits (256 increments)

Accuracy:

+/-0.7

°

RESOLVER(S)

Operating Temp:

-40

°

to 125

°

C (-40

°

to 257

°

F)

Storage Temp:

-40

°

to 125

°

C (-40

°

to 257

°

F)

Operating Humidity:

95% Relative non-condensing

NEMA Rating:

NEMA 4
NEMA 4X

Maximum RPM:

3000 RPM

Max Cable Length:

1000 Ft.

Type:

Single Turn - Brushless

Resolution (all):

12 Bits (4096 increments)

Linearity (standard):

+/-20 arc minutes (resolver only)
(+/-30 arc minutes combined with
R/D converter in controller)

Linearity (specials):

+/-3 to +/-10 arc minutes
(resolver only)
(+/-7 to +/-14 arc minutes
combined with R/D converter
in controller)

Note: A resolver's linearity errors are repeatable at all
positions of its 360 degree rotation. Therefore, once
appropriate setpoints are established, machine performance
is consistent every cycle.