Electrical specifications – Alto-Shaam QC2-3 User Manual

Page 13

Advertising
background image

Q U I C K C H I L L E R • I N S T A L L A T I O N / O P E R A T I O N / S E R V I C E M A N U A L • 1 1 .

S U b T I T l e

T I T l e

e l e c T r I c a l

I n S T a l l a T I o n

This appliance must be branch circuit protected with

proper ampacities, in accordance with the wiring

diagram. The Quickchiller must be properly grounded

in accordance with the National Electrical Code

and applicable local codes. Wire size for the main

incoming power to the unit must match the minimum

size listed in the specifications applicable to the

specific Quickchiller model. For supply connections,

locate the wire size listed in this manual.
Before operating the chiller, check all cable connections

in the electrical connection area for tightness since

connections can loosen during transport.
noTe: after electrical connections have been

completed, operate the appliance in any

chilling mode for a period of 15 minutes

and recheck the main power connections

at the terminal block to make certain they

remain tight.

d a n g e r

To avoid electrical shock, this
appliance MUST be adequately
grounded in accordance with local
electrical codes or, in the absence of
local codes, with the current edition
of the National Electrical Code ANSI/
NFPA No. 70. In Canada, all electrical
connections are to be made in
accordance with CSA C22.1, Canadian
Electrical Code Part 1 or local codes.

d a n g e r

ELECTRICAL CONNECTIONS MUST
BE MADE BY A QUALIFIED SERVICE
TECHNICIAN IN ACCORDANCE WITH
APPLICABLE ELECTRICAL CODES.

voltage

phase

cycle

/

hz

Qc2-3

Qc2-20

Qc2-40

Qc2-100

Self-conTaIneD

115V

1 ph

60 Hz

r

eCoMMeNded

CirCuit

aMperage

:

p

lug

CoNfiguratioN

:

16A, 1.84kW

20 amps

NEMA 5-20P

16A, 1.8kW

20 amps

NEMA 5-20P

Not

available

Not

available

Self-conTaIneD

115/208-230 1 ph

60 Hz

r

eCoMMeNded

CirCuit

aMperage

:

p

lug

CoNfiguratioN

:

Not

available

Not

available

16A, 3.8kW

20 amps

NEMA 14-20P

Not

available

Self-conTaIneD

115/208-230 1 ph

60 Hz

r

eCoMMeNded

CirCuit

aMperage

:

r

eCoMMeNded

wire

size

:

Not

available

Not

available

Not

available

24A, 5.76kW

30 amps

4 wire direct

Self-conTaIneD

115/208-230 3 ph

60 Hz

r

eCoMMeNded

CirCuit

aMperage

:

r

eCoMMeNded

wire

size

:

Not

available

Not

available

Not

available

16A, 6.64kW

20 amps

5 wire direct

reMoTe coMpreSSor

(cabinet only)

208-240VAC 1 ph 50/60 Hz

r

eCoMMeNded

CirCuit

aMperage

:

r

eCoMMeNded

wire

size

:

Not

available

Not

available

Not

available

contact

factory

elecTrIcal SpecIfIcaTIonS

Wire diagrams are located near the top of the
unit, close to the compressor or control panel.