Alto-Shaam QC2-3 User Manual

Page 16

Advertising
background image

Q U I C K C H I L L E R • I N S T A L L A T I O N / O P E R A T I O N / S E R V I C E M A N U A L • 1 4 .

T I T l e

o p e r a T I o n

aDDITIonal InforMaTIon

Clean the Quickchiller and probes prior to use

and make certain all processing modes are

operating properly before chilling or freezing

foods.

To maintain proper operation of the Quickchiller,

always allow the unit to defrost whenever the

DefroST overDUe” warning appears in

the display.

For optimum performance, allow the Quickchiller

to prechill for a minimum of 30 minutes before

loading pans of food.

Never overload the Quickchiller.

It is important to be familiar with and adhere to

all local food codes.

Cook foods properly in preparation for blast

chilling or freezing.

Foods should be portioned into shallow pans to a

depth not to exceed 2-inches (51mm).

Pans must be covered prior to the chilling or

freezing process.

Always follow the recommended shelf life for

chilled food products. Hold chilled foods

under refrigeration for a maximum of 5 days

including the day of production and the day

of consumption.

According to U.S. food code regulations, all

chilled products must be reheated to an internal

temperature of 165°F (74°C) prior to serving.

Door

If the Quickchiller door is opened during any

running chill or freeze cycle, the fans will disengage.

When the door is closed, the fans will reengage and

the chiller will resume operation. When the door

is opened, the display will reverse. When the unit

is in operation and not in the “off mode”, a “Door

open” message will appear on the display along with

the normal chill data. If the door is open for more

than 2 minutes, then the beeper will sound every 10

seconds.

fan operaTIon

During the initial cooling of the Quickchiller,

an evaporator fan delay system will prevent the

chilling fans from engaging until the evaporator

coil temperature is below 30°F (-1°C). The fans will

continue to run until the evaporator coil temperature

is above 60°F (16°C).
The Quickchiller will only trigger an automatic

defrost cycle during the refrigerated Hold temp

mode. If the chiller is in any other mode when the

6-hour Fan Timer limit plus one additional hour has

elapsed, the display will indicate a warning message

DefroST overDUe” and the control will produce an

audible signal every ten seconds until a defrost is

conducted.

poWer oUTaGe

poWer WaS off” will appear in the display

whenever operation is interrupted by a power

outage. The control will produce an audible signal

every 10 seconds and the display will indicate the

amount of time the power was off. If consecutive

power outages occur before the first outage has been

acknowledged, the control will accumulate the total

amount of outage time up to a period of 4 hours.

After a period of 24 hours, accumulated time will be

shown as greater than 24 hours, i.e.,

>24

.

press the proGraM key to clear the display and stop

the audible signal.

Advertising