Alto-Shaam QC2-3 User Manual

Page 23

Advertising
background image

Q U I C K C H I L L E R • I N S T A L L A T I O N / O P E R A T I O N / S E R V I C E M A N U A L • 2 1 .

8. haccp DoWnloaD

This is displayed only when the control is connected

to a USB DataLogger. [Optional feature]

With the HACCP Download selected, press the Start

key and insert USB data stick. Display will indicate

QC USB and the % status copied to USB data

stick. When 100% is displayed, transfer is complete.

Pull the data stick out of the data port. All data has

been transferred to the USB stick and is erased from

the control. A folder called "haccp" is created on the

USB data stick containing dated excel file names for

each chilling mode or defrost cycle since the last

HACCP download.

9. probe verIfIcaTIon

With the probe verification selected, press the Start

key to enter the probe verification mode.
The offset and the temperature will display for:

Top Probe (

where

appliCable

)

Middle Probe (

where

appliCable

)

Bottom Probe (

where

appliCable

)

If probe calibration is needed, place the probe

in a glass of ice-water and let the probe settle in

temperature. The temperature in the glass should be

32°F (0°C).

To calibrate, Press up5or down6arrow key to

adjust between the probes, and the right4or

left3arrow keys to adjust the calibration value.

Press the proGraM key to exit probe

calibration mode.

10. preSeT lock (0=

UNLOCKEd

, 1=

LOCKEd

)

I

o

If the presets are locked, pressing

start

on

the desired preset will skip the mode

overview and will start immediately.

Factory default is

locked

.

11. chIll MoDe lock (0=

UNLOCKEd

, 1=

LOCKEd

)

I

o

If the chill modes are locked, pressing the

chill mode button will skip the mode

overview and will start immediately.

Factory default is

unlocked

.

12. DefroST TIMe (MInUTeS)

This is the amount of time the defrost function

will run before automatically switching back to the

chilling mode. Factory default setting is 20 minutes.

The user may select a range from 10-30 minutes

using the right4or left3arrow key to increase or

decrease the numbers as required.