Alto-Shaam QC2-3 User Manual

Page 19

Advertising
background image

Q U I C K C H I L L E R • I N S T A L L A T I O N / O P E R A T I O N / S E R V I C E M A N U A L • 1 7 .

Q U I C K C H I L L E R • I N S T A L L A T I O N / O P E R A T I O N / S E R V I C E M A N U A L • 1 7 .

S U b T I T l e

T I T l e

c a u t i o n

ADEQUATE SPACING MUST
BE ALLOWED BETWEEN PANS
FOR PROPER AIR CIRCULATION
FOR BOTH PROCESSING AND
SUBSEQUENT HOLDING.

a D v a n c e D o p e r a T I o n

o p e r a T I o n

The date and time will appear in the display when

the unit is off. When the unit is turned on, the

screen will read: “SelecT MoDe or preSS STarT To

SelecT preSeT

To initiate any Quickchiller operating mode,

power must initially start from the

off

position

or an operating mode must be halted by pressing

the STarT/STop key so that the SelecTIon Screen

appears on the display.
noTe: With the exception of the QC2-3 counter top

Quickchiller model, the Alto-Shaam name on

the control panel will illuminate whenever

the power key is pressed to the

on

position.

holD TeMp

Starting from the

off

position, press the

power key

on

. The SelecTIon Screen will

appear on the display. The compressor will

become energized and will begin to operate

if required by the sensors.

Press the holD TeMp key. The display will

indicate the default hold temperature

(changeable in User Settings).

To change the displayed temperature, press the

up

5

or down

6

arrow key to increase or decrease

the temperature display within the refrigeration

storage parameters of the Hold temp mode -5°F to

+40°F (-21°C to +4°C).

note

:

THE

MOdIfIEd

HOLdINg

TEMPERATURE

SET

-

POINT

IS

NOT

SAVEd

.

THE

dEfAULT

HOLd

TEMPERATURE

CAN

bE

CHANgEd

UNdER

USER

SETTINgS

.

Press the STarT/STop key to begin

operation of the Quickchiller in the Hold

temp mode.

The display will indicate:

1. The length of time the chiller is

operating in the Hold temp mode.

2. The temperature set by the operator.
3. The air temperature inside the

chiller compartment.

4. The temperature of all food probes.

When In The holD TeMp MoDe afTer a chIll

MoDe:

Press the Up

5

arrow key to display the maximum

sensor temperature achieved during the completed

chill cycle. Press the DoWn

6

arrow key to display

the minimum sensor temperature achieved during

the completed chill cycle. Press the right

4

or

left

3

arrow key to display the Probe

Done Time.

c a u t i o n

NEVER STACK PANS DIRECTLY
ON TOP OF EACH OTHER.
STACKED PANS WILL RESTRICT
AIR FLOW AND INCREASE CHILL
PROCESSING TIME.

Advertising