Q U I C K C H I L L E R • I N S T A L L A T I O N / O P E R A T I O N / S E R V I C E M A N U A L • 4 .

InSTallaTIon reQUIreMenTS

The model QC2-3 is a counter mounted unit and

must

use legs that allow for a 4" (102mm) clearance

between the cabinet and the counter.

For all other

models, install

the appliance

on a smooth and level

floor surface. Use the adjustable cabinet legs

to level the Quickchiller.
Adjust from front-to-back and from side-to-side

with the use of a spirit level to evenly distribute

the cabinet weight and avoid pulling the cabinet

alignment out of square.
After leveling the cabinet, check that the door

handle is aligned properly. Also check the height

relationship of the optional roll-in cart to the

cabinet. Adjust the Quickchiller height as needed

to accommodate the cart and to securely close the

Quickchiller door.

Door Seal:

Check the door gasket to make certain it is sealing

properly and that the gasket provides an even and

positive seal around the entire door frame.

WaTer DraInaGe

A 1/2" I.D. (12,7mm) PVC pipe is furnished with

the QC2-100 model. Use PVC glue to attach the

pipe into the drain opening at the rear of the unit.

Insert the PVC pipe into the drain opening with

a 1/4" (6mm) clockwise turn. Connect the PVC

pipe to discharge through an indirect waste pipe

into an open-site drain by means of a 2" (51mm)

air gap. Connection must be within 10' (3m) of the

unit.
noTe: In the U.S.A., this equipment is to be

installed to comply with the Basic Plumbing

Code of the Building Officials and Co de

Administrators International, Inc. [BOCA],

and the Food Service Sanitation Manual of

the Food & Drug Administration [FDA].

DraInaGe:

Qc2-3

Qc2-20

Qc2-40

Evaporator pan: no InstallatIon rEqUIrEd

Qc2-100

onE (1) Floor draIn:

1/2" (12,7mm) dIamEtEr

c a u t i o n

TO PREVENT PERSONAL INJURY,

USE CAUTION WHEN MOVING OR

LEVELING THIS APPLIANCE.

I n S T a l l a T I o n

S I T e I n S T a l l a T I o n

40-7/8"

(1036mm)

14" (355mm)

Electrical

Connection

Condensate

Drain

51" (1294mm)

93-5/8" (2377mm)

35-1/2" (902mm)

40" (1015mm)

75-1/2" (1917mm)

77-5/8" (1970mm)

8" (203mm) Condensate Drain

ALTO SHAAM

Electrical Connection

19-5/8"

(498mm)

Qc2-100