Quick freeze, hard chill, soft chill, Manual operation, Factory default set points – Alto-Shaam QC2-3 User Manual

Page 20

Advertising
background image

Q U I C K C H I L L E R • I N S T A L L A T I O N / O P E R A T I O N / S E R V I C E M A N U A L • 1 8 .

S U b T I T l e

T I T l e

ManUal operaTIon

1.

Starting from the

off

position, press the

power key

on

.

The Alto-Shaam name will illuminate and the

SelecTIon Screen will appear on the display. The

compressor will become energized and will begin

to operate if required by the sensors.

2. Press the desired mode key.

The display will give an overview of the current

set-temperatures for the mode.

If the current settings are acceptable,

press the STarT/STop key to begin your

chill cycle.

If modifications are required, press the

proGraM key and proceed to step 3.

3. The display will require the operator to select

between chilling by probe or by TIMe.

Select the desired chill method (time or probe) by

pressing the right

4

or left

3

arrow keys.

Press the proGraM key to continue.

3a. If TIMe was selected, use the right

4

or left

3

arrow keys to highlight chill, hold, or time,

then press the up

5

or down

6

arrow keys to

change accordingly.

3b. If probe was selected, select top, middle and

lower probe using right

4

or left

3

arrow keys

and then press the up

5

or down

6

arrow keys to

change accordingly.

notE: QC2-3 and QC2-20 will display only

one probe.

4.

Once the desired settings are entered, press

the STarT/STop key to begin chilling.

chilling by Time

When chilling by time, the display will indicate

a count-down of the time, the air temperature,

and the temperature of each food probe. After

time has expired, the chiller will automatically

convert to the set holding mode.

chilling by probe

When chilling by probe, the display will indicate

the length of time the product has been chilling,

the interior compartment set temperature,

and the air temperature. The display will also

indicate the temperature of each probe along

with “

act

.” to advise the operator that the

individual probe is active. As each probe reaches

the set point value, the display will indicate

done

.” When all probes reach the individual set

point value, the chiller will automatically convert

to the holding mode.

note: When a removable probe is unplugged,

it is assumed to be at the set-point, and it will

display “

unplugged

” on the display instead of

the actual and temperature set points.

When In The holD TeMp MoDe afTer chIllInG by

probe:
Press the rIGhT

4

or lefT

3

arrow key to display the

length of time it took for each probe to achieve set

temperature.

these

data

are

retained

until

a

new

probe

cycle

is

completed

.

facTory DefaUlT SeT poInTS

QUIck freeZe, harD chIll, SofT chIll

a D v a n c e D o p e r a T I o n

o p e r a T I o n

Quickchiller >

Default Set points

preset

Mode

chill

probe

hold

1.

Beans

Hard Chill

14°F

38°F

38°F

2.

Beef

Hard Chill

14°F

38°F

38°F

3.

Casserole

Hard Chill

14°F

38°F

38°F

4.

Chicken Breast

Soft Chill

34°F

38°F

38°F

5.

Chicken Whole Hard Chill

14°F

38°F

38°F

6.

Duck

Hard Chill

14°F

38°F

38°F

7.

Fish

Soft Chill

34°F

38°F

38°F

8.

Ground Meat

Hard Chill

14°F

38°F

38°F

9.

Lamb

Hard Chill

14°F

38°F

38°F

10.

Lasagna

Hard Chill

14°F

38°F

38°F

11.

Pork

Hard Chill

14°F

38°F

38°F

12.

Potatoes

Hard Chill

14°F

38°F

38°F

13.

Rice

Hard Chill

14°F

38°F

38°F

14.

Sauce

Hard Chill

14°F

38°F

38°F

15.

Sheet Cake

Soft Chill

34°F @ 10 min.

38°F

16.

Soup

Hard Chill

14°F

38°F

38°F

17.

Stew

Hard Chill

14°F

38°F

38°F

18.

Stuffing

Hard Chill

14°F

38°F

38°F

19.

Turkey

Hard Chill

14°F

38°F

38°F

20.

Vegetables

Soft Chill

34°F

38°F

38°F

Advertising
This manual is related to the following products: